Application Summary
Quick-reference checklist of key requirements before and during application
-
1Compact as normal
Complete final compaction of the paving as normal. Ensure the surface and jointing sand are thoroughly dry and free from dirt — paving containing dampness will significantly reduce joint penetration.
-
2Sweep thoroughly to remove surplus sand
Following final compaction, sweep the area thoroughly to remove surplus sand. Ensure jointing sand has been fully removed from the chamfer. On non-chamfered paving, sweep sand at least 3–5mm from the surface. Ensure both sand and paver are completely dry.
-
3Stir contents well, then apply by watering can with rose
Stir the contents well. Resiecco is not much thicker than water and is easily applied using a watering can with a rose attached. For standard 100 x 200mm CBP, pour out 1 litre evenly over 2 m² — a manageable amount to squeegee. Ensure the rose is fitted.
-
4Leave 2–3 minutes, then squeegee off surplus
Leave Resiecco to sit on the surface for 2–3 minutes, then remove all surplus with the RESIBLOCK SQUEEGEE, working from the top and always towards you. The product will pool in the chamfers/joints and be absorbed by the kiln-dried jointing sand. On riven surfaces, rub product into the surface with a clean rag to prevent pooling in depressions.
-
5Clean all tools immediately with water and detergent
All uncured sealant and tools must be cleaned immediately using water and detergent. No specialist solvents required.
Full Application Instructions
Complete step-by-step guidance from surface preparation through to curing
Coverage is 1.5–4.0 m² per litre depending on joint width and paver porosity. Accurate application rates are critical to ensure full joint stabilisation — typically 1 litre per 2 m² for 100 x 200mm CBP. For other dimensions contact Resiblock's Technical Department. Resiecco is usually applied as a single coat system.
Resiecco is whitish in liquid state but becomes clear when dry, giving a very low satin sheen finish that in most cases does not darken treated surfaces — protecting materials while retaining their original colour.
Make sure the surface and jointing sand are thoroughly dry and free from dirt. Paving containing dampness will significantly reduce joint penetration. Ensure paving is thoroughly swept and that no jointing sand remains in the chamfers of the pavers. On non-chamfered paving, sand must be swept at least 3–5mm from the surface.
- Watering can with rose attached
- RESIBLOCK SQUEEGEE
- Plate compactor
- Stiff broom for sweeping
- Clean rag (for riven surfaces)
-
1Stir contents well
Thoroughly stir the contents of the container before use to ensure a uniform, well-mixed product.
-
2Apply by watering can with rose attached
Apply to the surface using a watering can with the rose attached. For standard 100 x 200mm CBP, pour out 1 litre evenly over 2 m² — a manageable amount to squeegee. Ensure the surface is evenly coated.
-
3Leave 2–3 minutes, then squeegee off all surplus
Leave to sit on the surface for 2–3 minutes, then remove all surplus with the RESIBLOCK SQUEEGEE. Work the product into the joints for maximum penetration. If applying to a riven surface, rub Resiecco into the surface with a clean rag to prevent pooling in depressions.
Drying time is dependent on ambient conditions resulting in water evaporation — cooler or humid conditions will extend drying time. Avoid walking on the sealed area for 2–4 hours after application, and do not drive motor vehicles on the surface for approximately 72 hours until the joints have hardened.
All uncured sealant and tools should be cleaned immediately using water and detergent. As a solvent-free product, no specialist solvents are required. Clean any accidental spills and splashes immediately.
Technical Datasheet
Product description, physical data, performance data and storage information
| Property | Specification | Notes |
|---|---|---|
| Product Type | Low viscosity thermoplastic-acryl copolymer emulsion jointing sand stabiliser | Water-based; solvent free; single component; micro-elastomeric |
| Suitable Substrates | CBP, Concrete Flags, Natural Stone | Also concrete slabs, exposed aggregate panels, architectural sections and blocks |
| Previously Sealed Surfaces | Cannot be used | Trial on an un-trafficked area first to confirm suitability |
| Fields of Application | Pedestrian areas, footpaths, precincts, car parks & ramps, driveways, patios, shopping malls | Safe for internal use; ideal for aggressive vacuum-swept shopping malls |
| Coverage | 1.5–4.0 m² per litre | Depending on joint width and paver porosity; 100 x 200mm CBP typically 2 m²/litre |
| Number of Coats | 1 coat (usually) | Fine aggregate can be added between 2 coats for anti-slip |
| Application Temperature | 10°C – 30°C | Do not apply below 10°C |
| Rain-Free Period | 24 hours | |
| Foot Traffic | 2–4 hours after application | |
| Vehicle Traffic | Approximately 72 hours | Until joints have hardened |
| Drying Time | Dependent on ambient conditions | Resulting in water evaporation |
| Finish | Very low satin sheen | In most cases does not darken treated surfaces — retains original colour |
| Heat Resistance | Withstands temperatures in excess of 100°C | |
| Flash Point | Not flammable | |
| Colour (wet) | Milky | Becomes clear when dry |
| Odour | Faint/soap | No unpleasant odours — solvent free |
| Viscosity at 20°C | 6.5 CPS | |
| Specific Gravity | Ca. 1.025 g/ml | |
| pH | 7.5–8.0 | |
| Boiling Point | Ca. 100°C | |
| Freezing Point | Ca. 0°C | Do not allow to freeze |
| Chemical Resistance | High degree of resistance to commercial chemicals | Unaffected by commercial de-icing salts |
| Shelf Life | 18 months (unopened containers) | 18 months from date of purchase |
| Storage | Store at 5°C – 30°C. Protect from frost. | Do not allow to freeze |
| Shipping | Not regulated | Not classified as hazardous |
| Tool Cleaning | Water and detergent | No specialist solvents required |
| Quality Standard | Manufactured under ISO 9002 | Satisfies requirements of Local Agenda 21 |
Typical values. Skid resistance — pendulum test. Abrasion data — C & CA Abrasion Machines, ref R G Chaplin, BCA April 1990; test results from Sadegzedeh and Kettle, Aston University, Concrete, May 1987.
| Skid Resistance (Pendulum Test) | Result |
|---|---|
| Concrete pavers — unsealed | 65 |
| Concrete pavers — Resiecco sealed | 59 |
| Abrasion Resistance — Depth of Abrasion (mm) | Control (no treatment) | 2 coats 20% Sodium Silicate | 2 coats Resiblock |
|---|---|---|---|
| w/c ratio 0.65 | 1.18 | 0.89 | 0.14 |
| w/c ratio 0.52 | 0.78 | 0.51 | 0.14 |
| w/c ratio 0.44 | 0.54 | 0.40 | 0.14 |
Specification Clause
For engineers & specifiers — solvent-free jointing sand stabiliser
The jointing sand stabiliser shall be a solvent-free, water-based thermoplastic-acryl copolymer emulsion, single component, having the following minimum properties:
- Solvent free and environmentally friendly, giving off no unpleasant odours, and safe for internal use.
- Single component, requiring no thinning or use of a reactive ingredient.
- Does not adversely affect slip/skid values (SRV) on suitable substrates — trial required on low porosity or wet-cast products.
- High degree of resistance to commercial chemicals and unaffected by commercial de-icing salts.
- Bind jointing sand and act as an anti-detritus coating, significantly reducing oil and dirt penetration.
- Withstand temperatures in excess of 100°C.
- Micro-elastomeric, allowing the pavement to retain its normal flexural qualities.
- Not flammable; not classified as hazardous for transportation.
- Capable of being easily removed to allow access to services below pavers.
The stabiliser shall keep jointing sand in place under most conditions, including water flows and vacuum sweeping, rendering the joints partially impermeable to water. It shall largely eliminate problems associated with paver destabilisation and rutting, and restrict weed and grass growth in the joints. The material shall have a proven safety and performance record of use on similar pavements to that used on this project.